  • AIS spol. s r.o. - Measuring and information technology for power engineering
    developed for the purposes of data concentration and protocol conversion Development of special conversion SW according to the user requirements SW development in close cooperation with customer Development of special communication HW on request Wide experience of AIS staff in the field or protocol conversion Typical applications Connection of old RTUs to new SCADA or new RTUs to old SCADA Conversion of older or odd communication protocols to IEC101 IEC103

    Original URL path: http://www.ais-brno.cz/industrial-communication.php?lang=en (2016-04-30)
    Open archived version from archive


  • AIS spol. s r.o. - Measuring and information technology for power engineering
    network Available redundant measurements are used for estimation of this vector i e voltages currents real and reactive power However the calculation algorithms are valid only for simultaneously measured data The inexactness of measured quantities comes from errors of individual parts of measuring chain in the switching station control system Another source of errors is asynchronous measurement of measured quantities and data delay in communication lines All these errors mean aggravation of exactness of calculations Relative phasors between network nodes are specific variables Methods of their measurement are synchronous by principle and they are not dependent on the error of amplitude The demands on their quality differ according to the way of their utilization Optimization of utilization of distribution networks with high load raises need of real time knowledge of actual steady operation and dynamic transitions Asynchronous real time measurement brings considerable errors to subsequent control processes and control system calculations Devices for synchronous measurement of voltage and current phasors improved communication between objects and dispatching centre and powerful computer hardware represent the solution of these problems Synchronous measurement plays key role for the estimation of high voltage network Practical experience shows that delay of information concerning changed measurement can

    Original URL path: http://www.ais-brno.cz/synchronous-measurement.php?lang=en (2016-04-30)
    Open archived version from archive

  • AIS spol. s r.o. - Measuring and information technology for power engineering
    is implemented in the distribution network 110 kV A short time verification operation and testing was performed in 2007 in the transmission network 400 220 kV The system is based on measurement and processing of three phase synchronous phasors of voltage and current The METEL PMU units used for measurement in the system measure the synchrophasors at fifty times per second rate i e with 20ms period The units conform to the international standard IEEE C37 118 2005 and they are fully comparable with other PMUs meeting the same standard The entire system is flexible and another user specific functions and application can be tailor made in the case of implementation of PMU WAMS in the specific networks The data from individual PMUs are sent to the central station where they are processed in real time and archived All communications meet the above stated standard A phasor data from other electric systems can be also processed in the system and the central station can send and receive data from a dispatcher control system The system functions allow to process and monitor data according to various user requirements e g monitoring of quick dynamic transient actions or slowly changing states of network components like line parameters User can work on line or export data for processing in other systems The outputs of individual software applications are visualized in the user client workstations connected to the central station The system is designed as open for all level cooperation with components or systems supplied by other suppliers and for effective complement of the control system functions There are a number of functions and applications available in WAM METEL system e g adviser for safety switching in high voltage networks monitoring of complex voltages and currents amplitudes and angles in and between network nodes

    Original URL path: http://www.ais-brno.cz/wams-metel.php?lang=en (2016-04-30)
    Open archived version from archive

  • AIS spol. s r.o. - Measuring and information technology for power engineering
    WAMS synchrophasors PMU Synchronous measurement WAM system METEL Applications Products overview Applications Estimation of Steady State of Electrical Network Monitoring of Frequency and Power Oscillations Fault Localization Measurement of Electrical Line Parameters Under Continuous Operation Support of Switching in Distribution

    Original URL path: http://www.ais-brno.cz/wams-applications.php?lang=en (2016-04-30)
    Open archived version from archive

  • AIS spol. s r.o. - Measuring and information technology for power engineering
    voltages for power supply of external devices Installation on DIN rail 35mm Phasor Measurement Unit FOTEL T version A Product Technical Specification Technical Specification GPS Technical Specification MPX Measurement of voltage and current synchrophasors Construction with configuration up to 3 inputs Direct connection to voltage instrument transformers Input voltage range 45 to 120 Vef Voltage rating input to output 2 5 kVef RS232 communication interface Communication speed 300 to 38400 bps High precision GPS time synchronization Power supply 20 60 V AC DC Installation on DIN rail 35mm Time Synchronization Unit SYTEL Product Technical Specification Material for Project Time synchronization of external devices 2 open collector outputs Independent parameterization of period and length of output pulses Precision of pulse leading edge better than 5µs RS232 service port High precision GPS time synchronization Power supply 24 60 V AC DC Installation on DIN rail 35mm Phasor Measurement Unit METEL Product Technical Specification Terminal programmable microcomputer for synchronous measurements Fast parallel measurements with data storage typically 10 kHz Measurement inputs adjusted to outputs of instrument transformers 6 analog inputs per unit High precision GPS time synchronization Wide range of communication options on physical layer 2 Ethernet 1 RS232 1 GSM GPRS and

    Original URL path: http://www.ais-brno.cz/products-overview-sm.php?lang=en (2016-04-30)
    Open archived version from archive

  • AIS spol. s r.o. - Měřicí a informační technologie pro energetiku
    700 měřených vstupů Předmětem podnikání jsou především následující oblasti činností Systémy synchronního měření WAM Wide Area Monitoring Vývoj programování a nasazování terminálů PMU Phasor Measurement Unit Realizace komunikačních zařízení pro přenos dat Vývoj programování a nasazování centrálních stanic PDC Phasors Data Concentrator Realizace aplikací využívajících synchronních dat Zařízení pro průmyslovou komunikaci Vývoj a programování komunikačních zařízení Řešení úloh koncentrace komunikací a konverze komunikačních protokolů Měření a automatizace Vývoj a nasazování

    Original URL path: http://www.ais-brno.cz/background.php?lang=cz (2016-04-30)
    Open archived version from archive

  • AIS spol. s r.o. - Měřicí a informační technologie pro energetiku
    2015 Referát pro konferenci CIRED 2013 Tábor Contribution to international conference CIRED 2013 Stockholm Contribution to international conference CIRED 2011 Frankfurt Contribution to international conference IEEE 2011 Roma Referát pro konferenci Control Of Power Systems 2010 Referát pro konferenci EGÚ Poděbrady 2010 Referát pro konferenci CIRED 2010 Tábor Referát pro seminář EGÚ Cyklus 2010 březen Prezentace z jednání PS03 CIRED 2009 Pavlov Referát pro konferenci Control Of Power Systems 2008

    Original URL path: http://www.ais-brno.cz/articles-reports.php?lang=cz (2016-04-30)
    Open archived version from archive

  • AIS spol. s r.o. - Měřicí a informační technologie pro energetiku
    je nasazeno na 42 rozvodnách další rozvodny jsou měřením fáze postupně vybavovány ČEZ Distribuce VČE zařízení METEL je nasazeno na 4 rozvodnách Mapa nasazení měření synchronních fázorů v ČR Měření a řízení ČEPS ovládací systém UVRc a rozvaděč poruchových hlášení v rozvodně 420kV Otrokovice ČEPS monitoring přepětí na vedení V413 v rozvodně 420kV Prosenice DINAS Svitavy vizualizace provozu tunelové pece ZČU Plzeň systém pro simulaci a analýzu dynamických dějů v elektrizačních sítích Konvertory přenosových protokolů 2002 AIL Lugano Švýcarsko konverze protokolů TG065 TG709 RIDAT na IEC870 5 101 2003 Stadtwerke St Gallen Švýcarsko konverze protokolu TG709 na IEC870 5 101 2003 ČEPS Praha konverze protokolu SPA BUS na IEC870 5 101 2004 2005 ENEE Tegucigalpa Honduras konverze protokolu FW537 na IEC870 5 101 2004 ACEA Řím Itálie konverze protokolů SINAUT 8FW SIMATIC N na IEC870 5 101 2004 Siemens Verona Itálie konverze protokolů SINAUT 8FW multipoint na IEC870 5 101 2004 2005 2008 NEK Bulharsko konverze protokolu TG709 na IEC870 5 101 vyvážený nevyvážený 2002 2011 EBERLE Německo konverze komunikace regulátoru EBERLE na IEC870 5 101 vyvážený nevyvážený IEC870 5 103 C37 118 2004 E ON JME Brno přenos dat protokolem IEC870 5 104 2006 LST Rakousko konverze protokolu BC216

    Original URL path: http://www.ais-brno.cz/references.php?lang=cz (2016-04-30)
    Open archived version from archive